The rest of the framework describes what to build, page by page. This page answers the question it cannot: in which order? Its first weeks are the design work: the workshops, the charter and the operating model. The 90 days end with your baseline maturity assessment.

Why this order

OCDFThis framework's recommended order, aligned with the CIS Controls ordering.

The ordering below deliberately mirrors the logic of the CIS Critical Security Controls: the controls are numbered roughly in order of foundational value, beginning with Control 1 for enterprise asset inventory and Control 2 for software inventory, and ending with Control 18, penetration testing. That ordering answers a question every new security leader faces from the business: "shouldn't we get a pentest first?" No. A penetration test against an organisation with no asset inventory, no MFA baseline and no tested backups mostly documents what you already know is missing. Inventory comes first, blast-radius controls next, and testing when there is something meaningful to test. Use the CIS ordering when explaining prioritisation to the business; it is independent, widely recognised and matches this guide.

  1. Mandate before machinery — authority and scope gaps poison everything built on top.
  2. You can't detect what you can't see — visibility precedes detection.
  3. Blast-radius controls beat detection breadth — MFA, offline backups and segmentation cap the damage of the incidents you will miss.
  4. Reporting readiness is a legal clock — the NIS2 24 h early warning must work before your first significant incident, not after.
  5. Only then: depth — hunting, validation, automation, Level 4 ambitions.

The first 90 days

OCDF

The first 90 days week by week: charter, applicability register and operating model first, then crown jewels, blast-radius controls, priority log sources and the incident plan with a reporting drill, ending with a baseline maturity assessment in week 12 The first 90 days week by week: charter, applicability register and operating model first, then crown jewels, blast-radius controls, priority log sources and the incident plan with a reporting drill, ending with a baseline maturity assessment in week 12

The 90 days as a table, with the page or tool for each step
Week Do Framework
1–2 Run the GOVERN navigator workshop; draft the charter including containment authority in §4 Navigator G1–G11, charter template
1–4 Regulatory applicability register: which laws, which entities, which countries; register with authorities where overdue This document, your national annex, and the regulatory selector
2–6 Decide the operating model, whether MSSP, tiered or capability-based, using the decision path Operating models
3–8 Crown-jewel workshop with the business, I1; C/I/A impact rating per service ID-3, CIA triad
4–10 Blast-radius sprint: MFA everywhere at P1, one offline or immutable backup copy restore-tested at P3, admin-path segmentation quick wins at P4 PROTECT
6–12 Onboard priority log sources 1–3, namely identity, endpoint and email, in-house or to the MSSP DETECT, DE-1 priority list
8–12 IR plan v1 + ransomware & breach playbooks; statutory reporting contacts and one reporting drill against the 24 h clock RESPOND, playbook template, your national annex
12 Baseline maturity self-assessment; publish the gap backlog Maturity self-assessment

Dependency warning: most of the 90-day steps depend on another department. Charter sign-off and the reporting drill are [GATE] dependencies, on management and on legal and the DPO. Log onboarding and the MFA rollout are [HARD] dependencies, on the system owners and the IAM team. See each function document's "External dependencies" table and the marker convention in Introduction. Secure named counterparts for every [HARD] on this plan before week 1; it is the most common silent killer of new CDC timelines.

Exit criteria for day 90: signed charter · applicability register · operating model decided · crown jewels agreed in writing · MFA coverage measured · one clean restore proven · identity+endpoint telemetry flowing · reporting drill executed.

Months 4–12

  • Detection: use cases for the top techniques in your threat profile, each with owner, ATT&CK mapping and runbook; establish the tuning loop and triage SLAs, per Running the CDC
  • Response: containment technically tested; tabletop with management; DFIR retainer if not in-house
  • Recover: RTO/RPO agreed for crown jewels; rebuild-from-known-good procedure drafted
  • Govern: quarterly executive reporting running; supplier security clauses in new contracts
  • Reassess maturity at month 12. For a NIS2 entity, Level 2 in every function is the legal floor and the first target; above it, set year-2 targets per function, such as RESPOND at 3 for an important entity or Level 3 across all functions for an essential one

What not to do in the first year

Practitioner

Penetration tests and red teaming before the foundations exist, since CIS puts penetration testing at Control 18 for a reason · threat hunting programme · SOAR platform selection · deception tech · Level 4 detection-as-code pipelines · custom threat intel platform. All valuable, and all wasted if attempted before the 90-day foundations exist. The most expensive failure mode in new CDCs is buying Level 4 technology for a Level 1 organisation.